REVERSE OSMOSIS SYSTEM PERFORMANCE

Quality Reverse Osmosis Water For:

 * Drinking Water  * Coffee & Tea  * Plants & Flowers  * Aquariums
 * Ice Cubes  * Juice & Beverages  * Steam Irons  * Humidifiers

Performance Specifications

Membrane Rating*
 Membrane Production

 114 - 151 lpd

 Membrane TDS Reduction

 95% minimum

* Measured at industry standard condition of 60 psi, 77 degree F, 500 ppm TDS, discharging to atmosphere
Contaminant Reduction Performance**

Solute

Rejection

 Solute

 Rejection

 Solute

 Rejection
 Barium

 99.5%
 Fluoride

 97.5%
 Radium 226/228

 80%
 Cadmium

 99.3%
 Lead

 99.5%
 Selenium

 96.9%
Chromium (as Cr+6)

 99.5%
 Mercury

 97.0%
 Sodium

 93.3%
Chromium (as Cr+3)

 99.5%
 Nitrate (as N)

 84.1%
   
 Copper

 99.4%
 Nitrite (as N)      
** For specific test parameters please email for performance data sheet
Incoming water specifications
 Water Pressure Range

 40 - 125 psi (275 - 860 kPa)

 Maximum Total Dissolved Solids (TDS)

less than 2000 mg/l

 Water Temperature Range

 40 - 110 deg F (4 - 43 deg C)

 Allowable pH Range

 5 - 10

 Maximum Hardness

 less than 170 mg/l or presoften

 Maximum Iron

 less than 0.1 mg/l

 Maximum Manganese

 less than 0.05 mg/l

 Hydrogen Sulfide Restriction

 none must be present

 Chlorine Restriction**

 none must be present

 Bacteria Restriction***

 none must be present

** Chlorine will damage a TFC membrane. The Carbon Prefilter included in the system will remove chlorine from feed water. Change filter every 6 months, more often if the water contains more than 1 mg/l chlorine.

*** Do not use these systems where the feed water is microbiologically unsafe or with water of unknown quality without adequate disinfection before or after the unit.

RETURN TO REVERSE OSMOSIS SYSTEM PAGE
RETURN TO CRYPTO/GIARDIA PAGE